Canon NP7161 User Manual Page 281

  • Download
  • Add to my manuals
  • Print
  • Page
    / 346
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 280
COPYRIGHT
©
1998 CANON INC. CANON NP7161/NP7160 REV.0 AUG. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 10 TROUBLESHOOTING
10–51
17.E800
Malfunction
Power supply PCB
DC controller PCB
1
2
YES
YES
NO
Turn off and then on the power switch. Is the
problem corrected?
Replace the power supply PCB. Is the
problem corrected?
End.
End.
Check the wiring and
continuity from the DC
controller PCB to the control
panel PCB; if normal, replace
the DC controller PCB.
Actions
ChecksStep
Cause
Yes/No
19.E821
Actions
ChecksStep
Cause
Yes/No
Ozone filter
Cleaner thermistor
(TH3)
DC controller PCB
YES
YES
NO
Replace the ozone filter. Is the problem
corrected?
Turn on the power switch, and select service
mode 111 (clean thermistor detection
temperature).
Do the reading remain as ‘111’?
End.
Check the wiring from J112
on the DC controller PCB to
the thermistor; if normal,
replace the thermistor.
Replace the DC controller
PCB.
1
2
Make the checks in step 2 and
later to identify the fan that
caused the error.
Connect the connectors.
End.
Check the wiring from the DC
controller PCB to the exhaust
fan; if normal, replace the DC
controller PCB.
18.E805
1
2
3
NO
YES
NO
Actions
ChecksStep
Cause
Yes/No
Check service mode '106' (E805 details)
while 'E805' is being indicated.
Are the connectors from the connector on the
DC controller PCB to the exhaust fan proper?
Replace the exhaust fan. Is the problem
corrected?
Connector
Exhaust fan
(FM2, FM4, FM5)
DC controller PCB
Page view 280
1 2 ... 276 277 278 279 280 281 282 283 284 285 286 ... 345 346