Canon VB-C500D User Manual Page 272

  • Download
  • Add to my manuals
  • Print
  • Page
    / 288
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 271
9-30
Messages List
VK-64/VK-16 Viewer Logs
A list of messages shown in the VK Viewer log file nvr_viewer_log_<N>.txt (<N> is either 0 or 1) is shown
below.
Log Storage Destination
The Storage Server logs are stored in the following folder in the PC where the Storage Server is
installed.
For Windows Vista/Windows Server 2008
<System drive>:\ProgramData\Canon\Webview\NVR
For OS other than Windows Vista/Windows Server 2008
<System drive>:\Documents and Settings\All Users\Application Data\Canon\Webview\NVR\logs
The Apache logs used by the Storage Server are stored in the following Storage Server installation
folder.
<Storage server installation folder>:\websrvr\logs\
The Viewer logs are stored in the following folder in the PC where the Viewer is installed.
For Windows Vista/Windows Server 2008
<System drive>:\ProgramData\Canon\Webview\NVR
For OS other than Windows Vista/Windows Server 2008
<System drive>:\Documents and Settings\All Users\Application Data\Canon\Webview\NVR\logs
Messages Cause Action
CHttpVbSetngThread:
inet error=<wininet
error code>, winsock
error=<Winsock error
code>,
count=<Number of
occurrences>
A network error occurred while
communicating with the camera server
(This is recorded when a problem
occurs in configuration protocol
communications).
See the corresponding Winsock error
code in "Error Codes in Log File" ( P.
9-31).
vbc_HttpCommand:in
et error=<wininet error
code>, winsock
error=<Winsock error
code>,
count=<Number of
occurrences>
A network error occurred while
communicating with the camera server
(This is recorded when a problem
occurs in WV-HTTP protocol
communications).
See the corresponding Winsock error
code in "Error Codes in Log File" ( P.
9-31).
Page view 271