Canon NP6317 Specifications Page 219

  • Download
  • Add to my manuals
  • Print
  • Page
    / 248
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 218
CHAPTER 10 TROUBLESHOOTING
COPYRIGHT
©
1999 CANON INC. CANON NP6317 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
10-55
31.
indicator does not go OFF
Action
Disconnect the shorting.
Either 24VDC or GND
is not connected to the
control card unit.
Explain to the user that
the indicator will not go
OFF unless a card other
than a department card is
inserted.
Continue with step 7.
Use another card.
Replace the control card
controller PCB.
Replace the control card
controller PCB.
Is the Control Card V
normal?
Use another card or
change the upper limit.
Replace the control card
controller PCB.
Check the wiring be-
tween the socket and the
DC controller PCB.
Replace the DC control-
ler PCB.
Result
No
No
No
Yes
No
No
Yes
No
No
Yes
Check
Is anything displayed on the control card
display?
Is a department card being used?
Take the card out completely; then, insert
it once again. Does "-EE-" appear on the
control card display?
Is there dirt on the card PCB, or is it bro-
ken, etc.?
Does the display in step 4 flash?
Borrow the upper limit setting card from
the user and check the departmental upper
limit flashing in step 5. Has the number of
copies reached the upper limit?
Set the power switch OFF. Put a test con-
trol counter into the socket. Disconnect
J314 from the DC controller. Set the meter
to the × 1 range. Connect the leads to
J316-1 and J504-4, and J316-2 and J504-
3. Does the meter indicate 0?
Procedure
1
2
3
4
5
6
7
Cause/Problem
area
Control Card
unit power
supply
Operation
Card
Card sensor
PCB
Controller
PCB
Controller
PCB
Wiring
DC controller
PCB
Page view 218