CHAPTER 3 EXPOSURE SYSTEM
COPYRIGHT
©
1999 CANON INC. CANON NP6317 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
3-17
C. Exposure Assembly
1. Detaching the Scanning Lamp
1) Disconnect the power plug.
2) Detach the copyboard glass.
3) Remove the two screws, and detach the
anti-glare plate.
4) Push the lamp terminal plate (rear) into
the direction of the arrow, and detach the
scanning lamp.
Note:
i. Wait until the scanning lamp has
cooled before starting the work.
ii. Do not leave fingerprints on the scan-
ning lamp.
iii. Dry wipe the scanning lamp if it is
soiled.
[2] [1]
[1] Screws [2] Anti-glare plate
Figure 3-510
[1] Lamp terminal plate (rear)
[2] Scanning lamp
Figure 3-511