Canon PC960 Specifications Page 352

  • Download
  • Add to my manuals
  • Print
  • Page
    / 393
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 351
CHAPTER 11 TROUBLESHOOTING
COPYRIGHT
©
1999 CANON INC. CANON PC800s/900s REV.0 AUG. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
11-87
Code Cause Description
The main motor (M1) is fault.
The DC controller PCB is faulty.
The composite power supply PCB is
faulty.
The DC controller PCB is faulty.
The scanner home position sensor
(PS1) is faulty.
The scanner/lens drive motor (M2)
is faulty.
The DC controller PCB is faulty.
The lens home position sensor
(PS2) is faulty.
The scanner/lens drive motor (M2)
is faulty.
The lens cable is faulty.
The DC controller PCB is faulty.
The scanning lamp (LA1) is faulty.
The DC controller PCB is faulty.
The composite power supply PCB is
faulty.
The DC controller PCB is faulty.
The composite power supply PCB is
faulty.
The frequency of the power supply
is faulty.
The composite power supply PCB is
faulty.
Data communication between the
copier and the ADF (faulty).
The DC controller PCB is faulty.
The composite power supply PCB is
faulty.
The rotation of the main motor deviates
(indicated by MLOCK=0) for 1 sec or
more while the main motor drive signal
(MMD=1) is being generated.
The actual output value of the compos-
ite power supply high voltage is differ-
ent from the setting value twice in
succession.
The scanner home position is not
detected within 10 sec after the scanner
has turned on.
The scanner does not leave the home
position after it has turned on.
The lens hoe position is not detected
after the lens has moved the maximum
travel distance.
The lens does not leave the home
position after it has turned on.
The lamp ON detection signal is not
detected for 1 sec or more in the
presence of the scanning lamp On
signal.
The lamp ON detection signal is
detected for 1 sec or more in the
absence of the scanning lamp ON
signal.
A fault in the communication between
DC controller PCB and composite
power supply PCB is detected.
The interval between zero-cross signals
is in excess of the allowed interval.
The communication with the copier is
interrupted for 5 sec or more; the
communication is monitored at all
times.
During a copying run, the +24 V power
deviates from the control value by
±20%.
The keys on the
control panel
are locked
without error
code indication.
( )
Page view 351