Canon VB-M40B User Manual Page 59

  • Download
  • Add to my manuals
  • Print
  • Page
    / 159
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 58
5-15
5
Setting Page
General Upload
[Upload]
Select [Upload Disabled], [HTTP Upload] or [FTP
Upload] for the upload method.
Note
The server or network load may increase and the frame rate may
drop, depending on the settings. If this occurs, try the following
measures. Also check the settings including the network to the
server.
Reduce the image file size:
Set a lower value under [Image Quality] for JPEG (p. 5-13).
Set a lower value for [Image Size: Upload] for JPEG
(p. 5-13).
Reduce the uploading frequency:
Reduce the value in [Pre-event Buffer (number of image
frames)] or [Post-event Buffer (number of image frames)]
(p. 5-20).
If [Volume Detection Event] is enabled, disable [ON Event
Operation] or [OFF Event Operation] (p. 5-20).
From the Intelligent Function Setting Tool [Event] tab >
disable [ON Event Operation], [OFF Event Operation] or
[Detected mode Operation] (p. 6-28).
If [External Device Input Event] is enabled, disable [ON
Event Operation] or [OFF Event Operation] (p. 5-21).
If [Timer Event Setting] is enabled, increase the value in
[Repeat Interval] (p. 5-22).
HTTP Upload
The HTTP upload function sends notifications via HTTP or
via HTTP with attached video, depending on the network
camera event.
(1) [Notification]
Select [Notification Only with HTTP] or [Image
attached Notification with HTTP] as the content of
notification.
(2) [URI]
Enter the URI to be uploaded to (using up to 255
characters).
(3) [User Name], [Password]
Enter the user name and password required for
authentication.
Digest authentication is not supported.
(4) [Proxy Server]
Enter the host name or IP address of the proxy server
(using up to 63 characters).
(5) [Proxy Port]
Enter the port number of the proxy server (factory
default setting is [80]).
(6) [Proxy User Name], [Proxy Password]
Enter the user name and password of the proxy
server.
Digest authentication is not supported.
[Upload]
Setting HTTP/FTP Upload and E-mail Notification
The following can be set here.
General Upload
Set the upload operation to be performed.
HTTP Upload
Set HTTP connection uploads.
FTP Upload
Set FTP connection uploads.
E-mail Notification
Set event information and image e-mail
notifications.
Important
If the upload function is used, either the [Event] menu must
be set (p. 5-20) or the [Event] tab in the Intelligent Function
Setting Tool (p. 6-25) must be set.
If you are using both e-mail notification by text and image
upload by HTTP/FTP, set [Image Size: Upload] (p. 5-13) to
[320 x 240] or less.
HTTP upload does not support SSL/TLS.
If the camera is set to perform upload or e-mail notification
continuously, not all images or e-mails may be sent
depending on the image size and the network condition to
the server. In this case, an event log message is displayed
(p. 5-33).
If the destination for HTTP/FTP upload or e-mail notification is
set for a Windows operating system, IPsec communication
cannot be applied.
Page view 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 158 159

Comments to this Manuals

No comments