Canon NP7161 User Manual Page 88

  • Download
  • Add to my manuals
  • Print
  • Page
    / 346
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 87
CHAPTER 4 IMAGE FORMATION SYSTEM
4–10
COPYRIGHT
©
1998 CANON INC. CANON NP7161/NP7160 REV.0 AUG. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
Figure 4-111
F1 F2 F3 F4 F5 F6 F7 F8 F9
-600
Developing
DC bias (V)
-500
-400
-300
-200
-100
Copy densityDarker Lighter
5
1
2
3
4
CPY
_
DNS
(V)
4. Controlling the Developing DC Bias to a Specific Voltage to Suit Copy Density
While copies are being made, developing AC bias and developing DC bias are applied to the
developing cylinder. The developing AC bias is 1400 Vp-p, and the developing DC bias may be
varied by sliding the Copy Density lever on the control panel.
When the Copy Density lever on the control panel is slid, the CPY_DNS signal will vary
between 1 and 5 V. The developing DC bias will then vary between -110 and -550 V.
Normally, the optimum image is obtained when the developing DC bias is set at -270 V
(CPY_DNS is 2.45V).