Chapter 5
 
5-28
F-5-9
NOTE:
If the print test is normal, make a copy of a document. If the copy is faulty, the reading section is faulty.
Please do not select the following menu:
3-1: CLR PTN1, 3-2: CLR PTN2
If a mistake is made and these menus are selected, the value of #7 PRINTER #5. INK ABS CAPA will be reset to 0%.
Replace the waste ink absorber and set to 0% in TEST mode.
5.7.5 FACULTY Tests
0004-3395
The faculty tests are selected by pressing the numeric key 6 or key from the test mode menu.
These tests check for the following faculties of the machine.
T-5-3
Test Type Overview
Sensor tests Test whether the sensors are operating correctly.
Operation panel test
Tests whether the key switches on the control panel
are operating correctly.
Line signal reception test Tests whether the NCU board signal sensor and
frequency counter are operating correctly.
Check for any vertical or horizontal white
stripes on the black squares.
Also, check that all the squares have
straight edges on all four sides.